This is from a text on laying wooden floors.

Il existe évidemment des règles objectives de contrôle de l’humidité du support. Le taux d’humidité doit être de maximum 2%. Et l’appareil qui permet de mesurer cela de façon précise s’appelle une « bombe à carbure ».

The translation "calcium carbide bus" can be found on proz.com, but when I google it, the term only exists on... you guessed it, proz.com

Thanks in advance for any help.
Proposed translations (English)
5 +2 carbide bomb

Discussion

Philip Taylor (asker) Oct 7, 2010:
Further along in the text:

La bombe à carbure est un appareil qui permet l’analyse chimique d’un extrait de votre chape. Vous ne trouverez pas cet outil partout, seuls les professionnels s’en servent. Insistez peut-être auprès d’un centre de location pour qu’ils s’en procure une : c’est un ustensile très intéressant., et facile d’utilisation.

Proposed translations

+2
10 mins
Selected

carbide bomb

The old carbide bomb test, (moisture test) which I used in the field many years ago.

The Calcium Carbide test is carried out using a ‘carbide bomb’ meter, which is a flask like device with a pressure gauge on the bottom. It is used widely in Europe and so it is common to find specifications related to this test, in most cases the readings from this meter should be less than 2.5 (according to DIN standards) for the concrete to be considered dry for flooring purposes
Peer comment(s):

agree kashew
19 mins
agree GeoS
1 day 15 hrs
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Many thanks."

Reference comments

30 mins
Reference:

The Calcium Carbide test

is carried out using a ‘carbide bomb’ meter, which is a flask like device with a pressure gauge on the bottom. It is used widely in Europe and so it is common to find specifications related to this test, in most cases the readings from this meter should be less than 2.5 (according to DIN standards) for the concrete to be considered dry for flooring purposes.

--------------------------------------------------
Note added at 37 minutes (2010-10-07 17:15:57 GMT)
--------------------------------------------------

Sorry, Bob, I only read your answer résumé!