"Prüfung nach FBL für Ampullen mit OPC"

What's FBL? Only Formblatt comes to mind, but ??

Thanks!
Change log

Mar 6, 2015 05:53: Lirka Created KOG entry

Mar 27, 2015 15:44: Harald Moelzer (medical-translator) changed "Field" from "Medical" to "Tech/Engineering"

Discussion

uyuni Feb 28, 2015:
@ Cornelia Lüttmann Sorry, but how come that you

1st merely repeat the answer I posted two hours prior to your entry using the identical source
2nd without providing a valid translation or at least making a suggestion
3rd all this at CL 5 (!)...?

Similar phenomenon in a subsequent thread:
http://www.proz.com/kudoz/english_to_german/medical_instrume...

Apologies, but I could not resist...
Donald Jacobson Feb 28, 2015:
Is there any more context? All I can find is:FBL - rRNA 2'-O-methyltransferase fibrillarin - Homo sapiens (Human)
www.uniprot.org/uniprot/P22087
Mobile-friendly - S-adenosyl-L-methionine-dependent methyltransferase that has the ability to methylate both RNAs and proteins.

Proposed translations

9 hrs
Selected

flaw assessment list/ fault rating list

or something similar...

FBL = "Fehlerbewertungsliste"

See page 21 @
http://www.pharmchem.tu-bs.de/forschung/waetzig/dokumente/dp...
which seems to meet the context given.

Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Thanks uyuni!"
2 hrs

flow-batch luminometer (FBL) testing (for One-Point Cut -OPC- Ampoules)

A flow–batch luminometer - ResearchGate
www.researchgate.net/publication/256814829_A_flowbatch_lumi...
The feasibility of the proposed flow–batch luminometer was demonstrated in the determination of vitamin B12 .... batch luminometer (FBL) for chemiluminescence measurements. ... The vitamin B12injection ampoules having a nominal content of .... connected to the PC. ... Recovery tests were also carried out adding 2.4 mL

A flow–batch luminometer - ResearchGate
www.researchgate.net/...flowbatch_luminometer/.../54b584410...‎Cached25 Oct 2012 ... posed flow–batch luminometer was demonstrated in the determination of vitamin
B12 in ... batch luminometer (FBL) for chemiluminescence measurements. ... The vitamin B12 injection ampoules having a nominal content of .... connected to the PC. ... Recovery tests were also carried out adding 2.4 mL.


--------------------------------------------------
Note added at 2 hrs (2015-02-28 03:10:24 GMT)
--------------------------------------------------

Cover image - ScienceDirect
www.sciencedirect.com/science/journal/0026265X/108
Decomposition test is applied by immersing Nafion in hydrogen peroxide at 80 °C for 0, 1, 4 and 8 h. .... ***A simple flow–batch luminometer (FBL) is presented. ... FBL was applied in the determination of vitamin B12 in injection ampoules***.
Peer comment(s):

neutral uyuni : One wouldn't say *nach* FBL then, *durch/mittels* rather..
6 hrs
Something went wrong...
11 hrs

Fehlerbewertungslisten

Fehlerbewertungsliste:
Standardisierte Bemusterung und Prüfung von Packmitteln;
Qualitätssicherung von Packmitteln in der Pharmaindustrie
Gemeinsam erstellt von Packmittelherstellern der Pharmaindustrie